Title Of Document
Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
Abstract
CISPR 16-2-1:2008+A1:2010 specifies the methods of measurement of disturbance phenomena in general in the frequency range 9 kHz to 18 GHz and especially of conducted disturbance phenomena in the frequency range 9 kHz to 30 MHz. This second edition of CISPR 16-2-1 cancels and replaces the first edition (2003) and its Amendment 1 (2005) and constitutes a technical revision. CISPR 16-2-1:2008 includes significant technical changes with respect to the previous edition. In general, this new edition aims at reducing compliance uncertainty in correspondence with findings in CISPR 16-4-1. Guidelines are given on - resonance-free connection of the AMN to reference ground, - avoidance of ground loops, and - avoidance of ambiguities of the test setup of EUT and AMN with respect to the reference ground plane. In addition, terms are clarified, a new type of ancillary equipment (CVP) is applied, and a clarification for the use of the AAN and AMN on the same EUT is provided. This consolidated version consists of the second edition (2008) and its amendment 1 (2010). Therefore, no need to order amendment in addition to this publication.
Category of Standards
Category 1
Previous Version
Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements / CISPR 16-2-1 : 2008 Ed 2.0
Document number assigned by ASEAN
CISPR 16-2-1 : 2010 Con Ed 2.1, 2010 (Incl Amd 1)
ICS
HS Range
MRA/Harmonised Regulations related to the Standard
Agreement on the ASEAN Harmonized Electrical and Electronic Equipment (EEE) Regulatory Regime
ASEAN Body responsible for Standard
Joint Sectoral Committee for Electrical and Electronic Equipment (JSC EEE)
Member States
BN ID KH LA MM MY PH SG TH VN
Date of harmonisation in ASEAN
28/06/2019
Date of Latest Review
Links :
CISPR 16-2-1:2008+AMD1:2010 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements